Line 6: Line 6:
* Type of LBPayLinker wiring cable (BC, IA or TOSEI)
* Type of LBPayLinker wiring cable (BC, IA or TOSEI)


== IA Machine ==
== TOSEI Machine ==
[[File:Tosei mesin.jpg|center|thumb]]


== Getting Started ==
== Getting Started ==
Line 17: Line 18:
![[File:1000030589.png|center|thumb]]A1
![[File:1000030589.png|center|thumb]]A1
|}
|}


2. Check LBPayLinker parts.
2. Check LBPayLinker parts.
Line 29: Line 29:
![[File:A1 tosei part.jpg|center|thumb|417x417px]]A1
![[File:A1 tosei part.jpg|center|thumb|417x417px]]A1
|}
|}


3. Connect the interface cable on the device.
3. Connect the interface cable on the device.
Line 37: Line 36:
![[File:A1 bc connection.jpg|center|thumb|400x400px]]A1
![[File:A1 bc connection.jpg|center|thumb|400x400px]]A1
|}
|}
4. Open Tosei machine cover.
4. Open Tosei machine cover.
[[File:Tosei open top cover.jpg|center|thumb]]
5. Switch off the machine.
6. Unscrew board cover to access the mainboard.
[[File:Tosei cover board remove.jpg|center|thumb|452x452px]]
7. Locate coindrop interface cable to machine board.
[[File:Locate tosei board cable.jpg|center|thumb|537x537px]]
8. Locate LBPayLinker machine wiring cable.


5. Locate power connector and disconnect it to shutdown the machine.
(1) Connect to the TOSEI board
6. Locate coindrop interface cable to machine board.


6. Locate coindrop interface cable to machine board.
(2) Connect to the TOSEI interface cable[[File:Tosei interface cable resize.jpg|center|thumb|435x435px]]


(1) Coindrop power to board


(2) Coindrop signal to board


9. Connect machine wiring cable Tosei type to coindrop - board cable.


7. Locate LBPayLinker machine wiring cable.
(1) Disconnect TOSEI interface cable from the board and connect it to the LBPayLinker wiring connector slot.


(2) Connect LBPayLinker wiring connector to the TOSEI board.
[[File:Install tosei interface cable.jpg|center|thumb|383x383px]]
[[File:Connect tosei cable to board.jpg|center|thumb|531x531px]]


8. Connect machine wiring cable Tosei type to coindrop - board cable.
10. Connect machine power source connector to the board.


(1) Disconnect coindrop power to board cable and connect with LBPayLinker coindrop wiring cable.
11. After installation, TOSEI screen will display error "Please use another machine".
[[File:Screen tosei after install device.jpg|center|thumb|415x415px]]
This indicate the device need to change the setting parameter for the machine. Next step is to configure the LBPayLinker device app through admin app. [[Configure device using admin app]]


(2) Disconnect coindrop signal to board cable and connect with LBPayLinker signal wiring cable.
== Installation video ==
Click link below to view installation video.


9. Connect machine power source connector to the board.
[https://lbunlimitedwash.com/lbwiki/video/TOSEI_Install.mp4 https://lbunlimitedwash.com/lbwiki/video/TOSEI_install.mp4]

Latest revision as of 02:48, 27 April 2026

Pre-requisites

[edit | edit source]
  • Open machine cover
  • Type of LBPayLinker devices (Model NYJ or A1)
  • Type of LBPayLinker wiring cable (BC, IA or TOSEI)

TOSEI Machine

[edit | edit source]

Getting Started

[edit | edit source]
  1. Make sure the LBPayLinker model Type. See picture.
NYJ31
A1

2. Check LBPayLinker parts.

  • For model NYJ31 - antenna and machine wiring cable
  • For model A1 - interface cable and machine wiring cable
NYJ31
A1

3. Connect the interface cable on the device.

NYJ31
A1

4. Open Tosei machine cover.

5. Switch off the machine.

6. Unscrew board cover to access the mainboard.

7. Locate coindrop interface cable to machine board.


8. Locate LBPayLinker machine wiring cable.

(1) Connect to the TOSEI board

(2) Connect to the TOSEI interface cable


9. Connect machine wiring cable Tosei type to coindrop - board cable.

(1) Disconnect TOSEI interface cable from the board and connect it to the LBPayLinker wiring connector slot.

(2) Connect LBPayLinker wiring connector to the TOSEI board.

10. Connect machine power source connector to the board.

11. After installation, TOSEI screen will display error "Please use another machine".

This indicate the device need to change the setting parameter for the machine. Next step is to configure the LBPayLinker device app through admin app. Configure device using admin app

Installation video

[edit | edit source]

Click link below to view installation video.